cGas Detector VRF IR Refrigerant Transmitter
An aesthetic, non-dispersive infrared refrigerant gas detector for acute leak detection in modern energy-efficient buildings utilizing Variable Refrigerant Flow (VRF) HVAC systems.
- Acute refrigerant leak detection
- Long life, non-dispersive infrared refrigerant sensor, dual beam technolog
- Easy Plug & Play Smart Sensor replacement at end of life, comes pre-calibrated
- Analog models - one field configurable 4 - 20 mA analog or 0 - 10 V output
Description
Designed with a sleek, low-profile aesthetic to blend seamlessly into publicly occupied spaces, the cGas VRF single-channel gas detector is ideal for modern energy-efficient buildings utilizing Variable Refrigerant Flow (VRF) HVAC systems. It provides continuous monitoring for refrigerant leaks in environments where gas accumulation could lead to oxygen depletion, ensuring occupant safety. It is secured by a mounting plate that can be used with or without a junction box.
The cGas VRF IR detector ensures occupant safety by meeting ASHRAE 15-2024 and CSA B52:23 standards for A2L and other refrigerants with alarm setpoints set well below the Refrigerant Concentration Limit (RCL) to provide early leak detection while minimizing false alarms. It features alarm levels designed to trigger ventilation, isolate or shut down refrigerant supply lines or trigger remote visual and audible alarms. The detector supports analog output as well as BACnet® and Modbus® communication protocols for integration with controllers or building automation systems. Designed with Plug & Play Smart Sensor Technology for easy installation and maintenance, it operates on 24 VDC or ground-referenced AC and includes an LCD display, internal buzzer, relay, temperature compensation, and a thermal resetting fuse. Firmware and configuration can be upgraded in the field via a USB connection, ensuring flexibility and long-term reliability.
Specifications
Target Gas
| A2L Infrared Refrigerant Sensors | R32, R454A, R454B, R454C, R455A, R1234YF, R1234ZE |
| Infrared Refrigerant Sensors | R134A, R404A, R407C, R410A, R449A |
Mechanical
| Enclosure | Polycarbonate, white, low profile |
| Weight | 400 g / 14 oz |
| Size | 124.9 x 124.9 x 50.0 mm / 4.9 x 4.9 x 2.0 in |
User Interface
| Display (Standard) | 2-line by 16 character graphic LCD configured for simple display mode Operating Temp: 0°C to 40°C / 32°F to 104°F |
| Push Buttons | Initiate calibration and menu options with internal UP, DOWN and ENTER push buttons |
| USB Port | Internal port for USB memory stick for field configuration updates / firmware upgrades |
Input/Output
| Analog Output (CGAS-AP models) | One field configurable 4 - 20 mA analog or 0 - 10 V, 2 - 10 V, etc. |
| Digital Output (CGAS-DP models) | Field configurable BACnet® MS/TP (version 1 rev 14) RS-485 or Modbus® RTU (version 1.1b3) RS-485 |
| Relay | 1 SPDT relay rated 30 volts, 2 amp max |
| Audible Alarm | Internal buzzer, rated 90 dB @ 10 cm / 4 in, enable/disable |
Electrical
| Power Requirement | 16-30 VDC, 3 W, Class 2 12-27 VAC, 50-60 Hz, 3 VA, Class 2 |
| Analog Wiring (CGAS-AP models) | VDC (or ground referenced AC): 3-conductor 16 - 18 AWG shielded, stranded within conduit VAC 4-conductor shielded 16 - 18 AWG stranded within conduit |
| Digital Wiring (CGAS-DP models) | VDC or VAC (ground referenced) 4-conductor 18 - 22 AWG twisted, shielded, stranded within conduit network wiring (daisy-chain) |
| Fuse(s) | Automatic resetting thermal |
Environmental
| Operating Temperature | 0°C to 40°C (32°F to 104°F) |
| Operating Humidity | 15 - 85% RH non-condensing |
Certifications
| Conforms to | CSA-C22.2 No. 205-12, UL508 (Edition 18):2018 EMC Directive 2014/30/EU, EN 50270:2015, Type 1, EN61010 FCC. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Listed by BTL RoHS compliant circuit boards |
Detected Gases
Configure Your cGas Detector VRF IR Refrigerant Transmitter
Select options below to filter configurations.78 configurations available
Showing 1–20 of 78 configurations
CGAS-O-HSG
CGas Office Mount Housing Assembly (no sensor)
CGAS-AP-CH2O
CGas Analog CH2O Transmitter (0-5 ppm), Public Space
CGAS-AP-CCH4-100-RLY
CGas Analog CH4 (methane) Transmitter 0-100% LEL w/Relay, public space
CGAS-AP-CO-RHT-RLY
CGas Analog CO Transmitter 0-200PPM w/RH & Temperature sensor and Relay
CGAS-AP-RD
CGas Analog Public Space Transmitter, 1 Channel Remote Dongle, Base Unit
CGAS-AP-RD-RLY
CGas Analog Public Space Transmitter, 1CH Remote, Relay Option
CGAS-AP-CO
CGas CO (0-200ppm) Analog Public Space
CGAS-AP-CO-RLY
CGas CO (0-200ppm) Analog Public Space w/ Relay
CGAS-DP-CO
CGas CO (0-200ppm) Digital Public Space
CGAS-DP-CO-RLY
CGas CO (0-200ppm) Digital Public Space w/ relay
CGAS-DP-CO-CO2-5K-RBZ
CGas CO 0-200ppm, CO2 0-5000ppm Digital public space with Relay and Buzzer
CGAS-AP-CO2-2K-RBZ
CGas CO2 0-2000 ppm Analog Transmitter - Public Space
CGAS-DP-CO2-2K-RHT
CGas CO2 (0 - 2,000 ppm) Office Mount w/ RH and Temp
CGAS-AP-CO2-2K
CGas CO2 (0-2000ppm) Analog Public Space
CGAS-DP-CO2-5%
CGas CO2 (0-5% Vol) Office Mount Digital Assembly
CGAS-AP-CO2-5K
CGas CO2 (0-5000ppm) Analog Public Space
CGAS-AP-CO2-5K-STVOC
CGas CO2 (0-5000ppm) Analog Public Space & TVOC
CGAS-AP-CO2-5K-RBZ
CGas CO2 (0-5000ppm) Analog Public Space, Relay Buzzer
CGAS-DP-CO2-2K
CGas CO2 0-2000ppm Office Mount Analog Assembly
CGAS-DP-CO2-2K-RBZ
CGas CO2 0-2000ppm Office Mount Analog Assembly w/ Relay, Buzzer
Not all configurations are listed here. Contact our sales team to discuss your specific requirements.
Documents
Application: Hotel Rooms - CGAS
PDF • 1.5 MB • Application Guides
A2L cGas Detectors Product Brochure
PDF • 2.6 MB • Brochures
cGas Detector VRF IR Brochure
PDF • 1.5 MB • Brochures
BTL Listing (PICS) for cGas Family
PDF • 202 KB • Certifications
cGas Detector VRF IR Datasheet
PDF • 500 KB • Datasheets
cGas Detector VRF IR vs cGas Detector IR
PDF • 379 KB • Datasheets
cGas Detector Public Spaces Installation Manual
PDF • 623 KB • Manuals
cGas Detector Public Spaces Operation Manual - firmware v2.05 onwards
PDF • 413 KB • Manuals
ChillerSense Solution Guide
PDF • 2.7 MB • Compliance Guides
cGas Modbus Holding Registers
PDF • 299 KB • Technical References