Critical Environment Technologies
    cGas Detector IR Refrigerant Transmitter

    cGas Detector IR Refrigerant Transmitter

    Non-dispersive infrared refrigerant gas detector with accurate, low level leak detection, available with analog output or BACnet® or Modbus® output and Plug & Play Smart Sensor Technology.

    • Accurate, low level and high level leak detection
    • Long life, non-dispersive infrared refrigerant sensor, dual beam technology
    • Easy Plug & Play Smart Sensor replacement at end of life, comes pre-calibrated
    • One linear 4-20 mA or 0-10V analog output or field configurable BACnet® MS/TP RS-485 or Modbus® RTU RS-485 digital output signal to a BAS

    Description

    The cGas Detector IR Refrigerant provides continuous monitoring of a wide range of refrigerant gases commonly used in commercial refrigeration systems. Dual beam, non-dispersive infrared sensor technology overcomes the limitations of solid state refrigerant sensors, accurately detects refrigerant gases without cross interference from toxic or combustible gases and is low maintenance with a longer lifespan. Choose from many types of refrigerant gas sensors commonly used in commercial refrigeration systems, including A2L refrigerants, SF6 and CO2 (R744). True Plug & Play Smart Sensor technology makes replacing sensors quick and easy.

    The cGas Detector IR Refrigerant is available with analog output or digital output and comes with a relay and internal audible alarm. Powered by 24 VDC or ground referenced AC, it has an LCD display, temperature compensation, thermal resetting fuse and the firmware and configuration can be upgraded in the field using the USB connection. It comes in a standard water / dust tight, corrosion resistant ABS/ polycarbonate enclosure with a hinged, secured door. With the optional, factory installed splash guard the enclosure is IP54 rated and provides protection in water spray or wash down applications.

    Complies with refrigeration safety codes ASHRAE No 15-2024 and B-52:23.

    Specifications

    Target Gas

    Infrared Refrigerant SensorR22, R123, R134A, R143A, R227ea, R404A, R407A, R407C, R407F, R410A, R417A, R422A, R422D, R427A, R434A, R438A, R442A, R448A, R449A, R450A, R452A, R453A, R507, R513A, R514A, HFO1233zd, RSF6, Carbon Dioxide (R744)
    A2L Infrared Refrigerant SensorR32, R454B, R1234yf, R1234ze

    Mechanical

    EnclosureBlack ABS / Polycarbonate, corrosion resistant, IP54 rated with splash guard installed (Option -S)
    Weight400 g / 14 oz
    Size127 x 127 x 76 mm / 5.0 x 5.0 x 3.0 inches

    User Interface

    Display (Standard)2-line by 16 character graphic LCD Operating Temp: 0°C to 40°C / 32°F to 104°F
    Display (low temperature Option -LT)2-line by 16 character OLED display Operating Temp: -40°C to 40°C / -40°F to 104°F
    Push ButtonsInitiate calibration and menu options with internal UP, DOWN and ENTER push buttons
    USB PortInternal port for USB memory stick for field configuration updates / firmware upgrades

    Input/Output

    Analog Output (CGAS-A models)One linear 4 - 20 mA analog or 0-10 V (user configurable in the field)
    Digital Output (CGAS-D models)BACnet® MS/TP (version 1 rev 14) RS-485 or Modbus® RTU (version 1.1b3) RS-485 (user configurable in the field)
    Relay1 SPDT relay rated 30 volts, 2 amp max
    Audible AlarmInternal buzzer, rated 90 dB @ 10 cm / 4 in, enable/disable

    Electrical

    Power Requirement16-30 VDC, 3 W, Class 2 12-27 VAC, 50-60 Hz, 3 VA, Class 2
    Analog Wiring (CGAS-A models)VDC (or ground referenced AC): 3-conductor 16 - 18 AWG (or larger) shielded, stranded within conduit VAC 4-conductor shielded 16 - 18 AWG stranded within conduit
    Digital Wiring (CGAS-D models)VDC or VAC (ground referenced) 4-conductor 18 - 22 AWG twisted, shielded, stranded within conduit, network wiring (daisy-chain)
    Fuse(s)Automatic resetting thermal

    Environmental

    Operating Temperature0°C to 40°C (32°F to 104°F) temperatures below 0°C / 32°F requires Option-LT
    Operating Humidity15 - 85% RH non-condensing

    Certifications

    Conforms toCSA-C22.2 No. 205-12, UL508 (Edition 18):2018 EMC Directive 2014/30/EU, EN 50270:2015, Type 1, EN61010 FCC. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Listed by BTL RoHS compliant circuit boards

    Documents

    Application: AI Workload Zones & Tower Stacks - FCS and CGAS-D-IR

    PDF • 3.8 MB • Application Guides

    Application: Chiller Rooms - cGas-SC and CGAS-A-IR

    PDF • 1.2 MB • Application Guides

    Application: Chiller Rooms - FCS and CGAS IR

    PDF • 933 KB • Application Guides

    Application: Hotels - FCS and CGAS IR

    PDF • 503 KB • Application Guides

    Application: Refrigerant Shafts - FCS and CGAS-D-IR

    PDF • 750 KB • Application Guides

    A2L cGas Detectors Product Brochure

    PDF • 2.6 MB • Brochures

    cGas IR Refrigerant Detector Brochure

    PDF • 760 KB • Brochures

    BTL Listing (PICS) for cGas Family

    PDF • 202 KB • Certifications

    Controls Schematic: Refrigeration System - Central Panel

    PDF • 801 KB • Controls Schematics

    Controls Schematic: Refrigeration System - Central Panel

    DWG • 1.3 MB • Controls Schematics

    Controls Schematic: Refrigeration System - Standalone Units

    DWG • 1.1 MB • Controls Schematics

    Controls Schematic: Refrigeration System - Standalone Units

    PDF • 402 KB • Controls Schematics

    Calibration Clip "Cal Clip" Datasheet

    PDF • 127 KB • Datasheets

    cGas Detector IR Refrigerant Datasheet

    PDF • 284 KB • Datasheets

    cGas Detector VRF IR vs cGas Detector IR

    PDF • 379 KB • Datasheets

    Splash Guard (Option -S) Datasheet

    PDF • 353 KB • Datasheets

    Engineering Spec: Refrigeration Machinery Room - FCS and CGAS-D-IR

    DOCX • 384 KB • Engineering Specs

    Gas Detection Schedule: Refrigeration System - Central Panel

    PDF • 171 KB • Gas Detection Schedules

    Gas Detection Schedule: Refrigeration System - Central Panel

    XLSX • 19 KB • Gas Detection Schedules

    Gas Detection Schedule: Refrigeration System - Central Panel

    DWG • 63 KB • Gas Detection Schedules

    Gas Detection Schedule: Refrigeration System - Standalone Units

    XLSX • 18 KB • Gas Detection Schedules

    Gas Detection Schedule: Refrigeration System - Standalone Units

    PDF • 169 KB • Gas Detection Schedules

    Gas Detection Schedule: Refrigeration System - Standalone Units

    DWG • 48 KB • Gas Detection Schedules

    cGas Detector Installation Manual

    PDF • 676 KB • Manuals

    cGas Detector Operation Manual - firmware v2.05 onwards

    PDF • 634 KB • Manuals

    cGas Detector Operation Manual - up to firmware v2.04

    PDF • 1.3 MB • Manuals

    Internal Heater for Cold Environment Applications

    PDF • 180 KB • Product Guides

    Product Spec: CGAS-A-IR Infrared Refrigerant Sensors

    PDF • 134 KB • Product Specs

    Product Spec: CGAS-A-IR123 Infrared Refrigerant Sensor

    PDF • 134 KB • Product Specs

    Product Spec: CGAS-A-IR32-100 A2L Infrared Refrigerant Sensor

    PDF • 134 KB • Product Specs

    Product Spec: CGAS-A-IR454B-100 A2L Infrared Refrigerant Sensor

    PDF • 134 KB • Product Specs

    Product Spec: CGAS-D-ICH4 Methane Infrared Sensor

    PDF • 134 KB • Product Specs

    Product Spec: CGAS-D-IR Infrared Refrigerant Sensors

    PDF • 136 KB • Product Specs

    Product Spec: CGAS-D-IR123 Infrared Refrigerant Sensor

    PDF • 142 KB • Product Specs

    Product Spec: CGAS-D-IR32-100 A2L Infrared Refrigerant Sensor

    PDF • 135 KB • Product Specs

    Product Spec: CGAS-D-IR454B-100 A2L Infrared Refrigerant Sensor

    PDF • 135 KB • Product Specs

    ChillerSense Solution Guide

    PDF • 2.7 MB • Compliance Guides