cGas-SD Sample Draw System
A Self-contained, single sensor sample draw gas detection system that draws sample air from locations where it is difficult to install a gas detector.
- Single chanel, 1 internal sensor
- 2x16 character LCD display with LED indicators
- Easy access push buttons on the front of the enclosure for configuration and calibration
- Line voltage 100 - 240 VAC, field configurable low voltage 24 VDC or 24 VAC power
Description
The cGas-SD is a self-contained, single sensor, sample draw monitoring system that is designed to draw samples of air from hard to access locations such as shafts, tall ceilings, wells, pits, small rooms and many other locations where it is difficult to install gas detectors. The CGAS-SD-O2 model is designed for use in rooms where compressed gases are used, such as in MRI and NMR rooms. Compressed gases and cryogenic liquids (usually nitrogen, helium and sometimes carbon dioxide) when dispensed, will displace Oxygen, creating an Oxygen deficient or hazardous atmosphere. Continuous monitoring of the Oxygen levels in these rooms is recommended to ensure the Oxygen levels remain safe and people inside the rooms are alerted in the case of a gas leak situation.
The cGas-SD system is designed to be installed outside the target location, at a viewable height, with sample tubing running from the monitoring system to the sampled environment. The sample draw pump pulls air from the area through the tubing, in through the inlet port and over the sensor. The air is then exhausted through the outlet port. If the gas readings are higher than a specified set point, the cGas-SD will go into alarm.
The cGas-SD can be configured with a toxic gas, oxygen or refrigerant sensor and comes with a flow detector, a sample draw pump and an internal adjustable flow meter. Features include one configurable analog output, one alarm level line voltage relay with field configurable time delays and trigger levels, a blocked flow alarm indicating a dirty filter or clogged tubing and an LCD display with LED indicators for channel alarm status and fault conditions.
The filter should be replaced when it becomes dirty and the tubing should be checked regularly to ensure it remains unblocked. For the best response, the sample tubing between the sample point and the inlet port should be kept as short as possible. The device has been factory tested with a maximum of 15 m / 50 ft of sample tubing. The type of gas, diameter and length of tubing will affect the rate of air flow. Testing should be done if longer tubing is required to make sure the air flow is not less than 1L/min.
NOTE: The cGas-SD is NOT available with solid state refrigerant sensors or combustible sensors. Solid state refrigerant sensors do not provide adequate stability; combustible gases can be an ignition source. Should there be a blockage, the pump will pressurize the system, increasing the possibility of combustion/explosion. The material of the valves and diaphragm is not compatible with combustible gas types and the pump is not intrinsically safe.
Specifications
Target Gas
| Gas Sensors | Ammonia (NH3), Carbon Monoxide (CO), Hydrogen Sulphide (H2S), Nitric Oxide (NO), Oxygen (O2), Sulphur Dioxide, (SO2), Refrigerants |
Mechanical
| Enclosure | Polycarbonate, water/dust tight, corrosion resistant |
| Weight | 2.7 kg / 6.0 lbs |
| Size | 25.8 x 26.8x 19.9 cm / 10.14 x 10.54 x 7.84 in |
| Tygon Polymer Tubing (sold separately) | 1/8" ID x 1/4" OD, clear, 15 m / 50 ft roll sold separately (p/n: CET-8000-CMT) |
| Teflon Lined Tubing (sold separately) | For use with CGAS-SD-7NH3, special non-absorbent, 13/16" ID x 5/16" OD, clear, 15 m / 50 ft roll sold separately (p/n: CET-8000-CTRL) |
Input/Output
| Output | One 4 - 20 mA analog output, jumper selectable 0 - 10 volts, 2 - 10 volts output User selectable BACnet® MS/TP (version 1 rev 14) RS-485 or Modbus® RTU (version 1.1b3) RS-485 |
| Relay | One SPDT dry contact relay rated 5 amps @ 240 VAC |
| Flow Rate | Normal operation: 0.5 - 1 LPM Flow Rate Alarm: 0 LPM |
| Blocked Flow Alarm | Door mounted buzzer, rated 90 dB @ 30 cm / 1 ft |
User Interface
| Display | 2x16 character LCD display LED indicators for alarm status 1, 2 and 3 for any channel and FAULT |
| External Push Buttons | Initiate calibration and menu options with easy to accessl UP, DOWN and OK push buttons |
Environmental
| Operating Temperature | 0°C to 40°C / 32°F to 104°F |
| Operating Humidity | 15 - 90% RH non-condensing |
| Location | Indoor use only. Not for use in classified hazardous areas or to sample draw combustible gases. |
Electrical
| Power Requirement | Line Voltage (standard) 100-240V AC +/-10%, 50/60 Hz, 20W, 1-phase or Low Voltage (field configurable) 16-30VDC / 12-28 VAC, 50/60 Hz, 20W |
| Wiring | Line Voltage: VAC three-conductor (Line, Neutral, Ground) shielded 14-18 AWG stranded within conduit or Low Voltage: 24VDC or 24VAC two-conductor shielded 14-18 AWG stranded within conduit |
| Fuses | Thermal, resetting |
Certifications
| Conforms to | CSA-C22.2 No 61010-1, UL 61010-1 (Edition 3) FCC. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. RoHS compliant circuit boards |
Configure Your cGas-SD Sample Draw System
Select options below to filter configurations.12 configurations available
Showing 1–12 of 12 configurations
CGAS-SD-CO
CGAS Sample Draw CO
CGAS-SD-NO
CGAS Sample Draw NO
CGAS-SD-O2
CGAS Sample Draw Oxygen
SD-IFA
Filter, serviceable , 1/8 " Hose Barb, In Line 74 micron
CGAS-D-SR402A
Solid state refrigerant (R402A) sensor (0-2000ppm)
CGAS-SD-H2S
Electrochemical hydrogen sulphide (H2S) sensor (0-50ppm), Tyon tubing sold separately
CGAS-SD-SO2
Electrochemical sulphur dioxide (SO2) sensor (0-20ppm), Tyon tubing sold separately
CGAS-SD-7NH3
Electrochemical 7 series ammonia (NH3) sensor (0-500ppm), Teflon tubing sold separately
CGAS-SD-7CO
Electrochemical carbon monoxide (CO) sensor (0-200ppm), Tyon tubing sold separately
CGAS-SD-7H2S
Electrochemical 7 series hydrogen sulphide (H2S) sensor (0-50ppm), Tyon tubing sold separately
CGAS-SD-IR134A
Infrared refrigerant (R134A) sensor (0-2000ppm), Tyon tubing sold separately
CGAS-SD-IR513A
Infrared refrigerant (R513A) sensor (0-2000ppm), Tyon tubing sold separately
Not all configurations are listed here. Contact our sales team to discuss your specific requirements.
Documents
Application: MRI Rooms - CGAS-SD-O2
PDF • 584 KB • Application Guides
cGas-SD Sample Draw System Brochure
PDF • 1.2 MB • Brochures
cGas-SD Oxygen Sample Draw Datasheet
PDF • 260 KB • Datasheets
cGas-SD Sample Draw Datasheet
PDF • 262 KB • Datasheets
cGas-SD Sample Draw System Installation Manual
PDF • 1012 KB • Manuals
cGas-SD Sample Draw System Operation Manual
PDF • 639 KB • Manuals
cGas-SD and DCC-SD / MRI Comparison Guide
PDF • 76 KB • Product Comparisons
Quick Reference Guide to the cGas-SD Sample Draw System
PDF • 234 KB • Product Guides