Critical Environment Technologies
    LNK-XT Network Extender Peripheral Device

    LNK-XT Network Extender Peripheral Device

    Works as signal booster and allows a longer distance between devices. Ideal for large applications to create an efficient distribution network of specialized gas detection devices that can communicate over large distances.

    • Extends transmission range of the Modbus® network
    • Boosts communication signal strength
    • Power LED indicator
    • Modbus® RS-485 RTU communication

    Description

    The LNK-XT Network Extender peripheral device works as a signal booster allowing transmission and receipt of gas readings over a larger total area. It extends the range of the Modbus® communication network allowing a longer distance between the FCS Multi System Controller and the gas detectors. The micro controller quickly passes Modbus information packets from the master side of the LNK-XT to the extension side, seamlessly without interruption.

    Multiple LNK-XT peripheral devices may be required depending on the size of the application. An LNK-XT is recommended every 2000 ft, approximately every 32 transmitters. Ideal for large applications to create an efficient distribution network of specialized gas detection devices that can communicate over large distances.

    Specifications

    Mechanical

    EnclosureABS / Polycarbonate, corrosion resistant
    Weight400 g / 14 oz
    Size127 x 127 x 71 mm / 5.0 x 5.0 x 2.8 inches

    User Interface

    IndicatorLED green indicator for power

    Input/Output

    CommunicationBidirectional Modbus® RS-485 RTU Baud Rate: 19,200

    Electrical

    Power Requirement24 VDC, 1W, Class 2 (24 VDC supplied by the Controller or RPS-24VDC)
    WiringVDC supplied by the Controller, 18 - 22 AWG twisted, shielded, stranded within conduit network wiring (daisy-chain)
    FusesThermal, resetting

    Environmental

    Operating Temperature-20°C to 40°C (-4°F to 104°F)
    Operating Humidity15 - 90% RH non-condensing

    Certifications

    Conforms to:CSA-C22.2 No. 205-12, UL508 (Edition 17):2007 EMC Directive 2004/108/EC, EN 50270:2006, Type 1, EN61010 FCC. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. RoHS compliant circuit boards

    Configure Your LNK-XT Network Extender Peripheral Device

    Select options below to filter configurations.3 configurations available

    Showing 1–3 of 3 configurations

    Product Code
    Qty
    Actions

    LNK-AI

    FCS Network Analog Input

    LNK-AO

    FCS Network Analog Output

    LNK-XT

    FCS Network Modbus extender, RS485

    Not all configurations are listed here. Contact our sales team to discuss your specific requirements.

    Documents

    LNK-XT Datasheet

    PDF • 189 KB • Datasheets

    LNK-XT Operation Manual

    PDF • 402 KB • Manuals

    Wiring Diagram: LNK-XT Powered by Controller

    PDF • 109 KB • Wiring Diagrams

    Wiring Diagram: LNK-XT Powered by RPS-24VDC

    PDF • 112 KB • Wiring Diagrams