LNK-AI Analog Input Peripheral Device
Adds 4 additional analog inputs to a gas detection system
The LNK-AI Analog Input peripheral device adds four channels of 4 - 20 mA or 0 - 10 volt analog inputs to a Modbus® network configured with an FCS Flexible Control System Controller
Applications
- Parking Facilities
- Vehicle Repair Shops
- Manufacturing Plants
- Food Processing Plants
- Arenas and Pools
- and many more...
Key Features
- Four 4-20 mA input channels
- Power LED indicator
- Modbus® RS-485 RTU communication
- Scaling and zoning capabilities supported by the ontroller
- Configurable default settings for any interruption in communication
- Standard water / dust tight, corrosion resistant enclosure
Description
The LNK-AI Analog Input peripheral device adds four channels of 4 - 20 mA or 0 - 10 volt analog inputs to a Modbus® network configured with an FCS Flexible Control System Controller.
The LNK-AI is designed to receive an analog signal from one to four transmitters and communicates back to the FSC using Modbus® RS-485. The FCS monitors the connection and will indicate a loss of communications.
Ideal for large applications to create an efficient distribution network of specialized gas detection devices with fewer wires running directly from the controller.
Specifications
Mechanical
Enclosure
ABS / Polycarbonate, corrosion resistant
Copper coated interior to reduce RF interference
Weight
400 g / 14 oz
Size
127 x 127 x 71 mm / 5.0 x 5.0 x 2.8 inches
User Interface
Indicator
LED green indicator for power
Input/Output
Output
Four 4-20 m A (2 - 10 volts is obtainable using a 500 Ohm resistor)
Communication
Modbus® RS-485 RTU
Electrical
Power Requirement
24 VDC, 1W, Class 2 (24 VDC supplied by the Controller)
Power Consumption
1 watt (not including the devices connected to it)
Wiring
4-conductor shielded minimum 18 AWG stranded within conduit
Fuses
Thermal, resetting
Environmental
Operating Temperature
-20°C to 40°C (-4°F to 104°F)
Operating Humidity
15 - 90% RH non-condensing
Certifications
Conforms to:
CSA-C22.2 No. 205-12, UL508 (Edition 17):2007
EMC Directive 2004/108/EC, EN 50270:2006, Type 1, EN61010
FCC. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
RoHS compliant circuit boards
Product Codes
Product Codes
LNK-AI
Remote Analog Input Peripheral Device, four 4-20 mA inputs, power LED indicator, Modbus® RS-485, water / dust tight, corrosion resistant enclosure
Compatible Devices
FCS-M or FCS-B
128 channel high performance Controller with logic control and priority settings for large gas detection applications
FCS-8-M or FCS-8-B