LPT-B BACnet® Transmitter

    Key Features

  • » 
    1, 2 or 3 channel operation
  • » 
    BACnet® MS-TP digital output signal
  • » 
    4-wire VAC / VDC
  • » 
    One SPDT dry contact relay (30 volts, 2 Amps max)
  • » 
    Graphic LCD display (user selectable function)
  • » 
    Internal audible alarm
  • » 
    Standard water / dust tight, corrosion resistant enclosure (drip proof). IP54 rated with optional splash guard installed
  • » 
    RoHS compliant package
The LPT-B is a full featured, 1, 2 or 3 channel, digital transmitter for use in non-hazardous, non-explosion rated, commercial and light industrial applications. It is available with a wide range of internal and/or external sensors and sensor types including electrochemical, solid state, catalytic and PID. The LPT-B may be configured to operate as a standalone fixed system or be part of a digital network. It offers a BACnet® MS/TP output signal for communicating with a Controller or Building Automation System, an audible internal alarm, one SPDT dry contact relay, LCD display with user selectable functions, temperature compensation and thermal resetting fuses all in a RoHS compliant package. 
 
The LPT-B comes in a standard water / dust tight, corrosion resistant ABS / polycarbonate enclosure with a hinged, secured door. It is IP54 rated with the optional splash guard installed which provides protection in water spray or wash down applications. An optional heater is available for continued operation in cold environment applications.
 
The LPT-B is not compatible with CETCI’s Controllers. It is intended to be used alone or integrated into an existing BACnet® network.
 
 

APPLICATIONS

  • » 
    Parking Garages/Car Parks
  • » 
    Vehicle Repair Shops
  • » 
    Recreational Facilities
  • » 
    Ice Cleaning Machine Rooms
  • » 
    Manufacturing Plants
  • » 
    Maintenance Facilities
  • » 
    ... and many more

Gas Types

Ammonia (NH3)
Carbon Monoxide (CO)
Combustible Gas (catalytic)
Ethylene (C2H4)
Fluorine (F2)
Hydrogen Fluoride (HF)
Hydrogen Sulphide (H2S)
Nitrogen Dioxide (NO2)
Nitric Oxide (NO)
Sulphur Dioxide (SO2)
TVOCs (solid state)
Silane (SiH4)
Phosphine (PH3)
Oxygen (O2)
Hydrogen Cyanide (HCN)
Hydrogen Chloride (HCl)
Hydrogen (H2)
Formaldehyde (CH2O)
Ozone (O3)
Refrigerants (R22, R134A, R401A, R402A, R404A, R407C, R410A, R422A, R422D, R438A, R507A)
Ethylene Oxide (C2H4O)
Chlorine Dioxide (ClO2)
Chlorine (Cl2)

Sensors

Mechanical

Enclosure:
ABS / Polycarbonate, corrosion resistant, drip proof; Copper coated interior to reduce RF interference.
Weight: 400 g (14 oz)
Size: 5.0” x 5.0” x 2.8” (127 mm x 127 mm x 71 mm)
Display Border Colour: Yellow

Electrical

Power Requirement:
12-27 VAC, 50-60 Hz, 3 VA, Class 2
16-30 VDC, 3W, Class 2
Wiring: 4-wire VDC / VAC, 16 gauge, 4-conductor shielded network wiring (daisy-chain)
Fuses: Thermal, resetting

Input / Output

Output: BACnet® MS/TP
Relay: One SPDT dry contact, rated 30 volts, 2 amps max
Audible Alarm: Standard internal buzzer, enable/disable

User Interface

Display: Graphic LCD, yellow border
Magnetic Sensors:
Using a magnetic wand, initiate calibration without opening the enclosure

Environmental

Operating Temperature: -20°C to 40°C (-4°F to 104°F)

NOTE: Low temperature optional available to -40°C (-40°F).
Humidity: 15 - 90% RH non-condensing


Note: Measurements above are sensor dependent.

Certifications

Conforms to: CSA-C22.2 No. 205-12, UL508 (Edition 17):2007
Conforms to: EMC Directive 2004/108/EC
                        EN 50270:2006, Type 1, EN61010
Conforms to:  FCC. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Listed by BTL

More Brochures

Product Specifications

Application Brochures

Drawings

Software

Sensor Specification

Engineering Specification Samples

DataSheets

Operation Manual

Part Numbers

Description Code
Single channel, no internal sensor (set up to accept an ESH-A remote sensor), LCD display LCD display, BACnet® MS/TP communication, 2 A @ 30 VAC / VDC SPDT relay, audible alarm, water / dust tight enclosure  LPT-B-R
Single channel, electrochemical ammonia (NH3) sensor (0 - 500 ppm range), LCD display, BACnet® MS/TP communication, 2 A @ 30 VAC / VDC SPDT relay, audible alarm, water / dust tight enclosure  LPT-B-NH3
Single channel, internal electrochemical 6-year carbon monoxide (CO) sensor (0 - 200 ppm range), LCD display, BACnet® MS/TP communication, 2 A @ 30 VAC / VDC SPDT relay, audible alarm, water / dust tight enclosure  LPT-B-TCO
Dual channel, internal electrochemical 6-year carbon monoxide (CO) sensor (0 - 200 ppm range), must add ESH-A remote sensor, LCD display, BACnet® MS/TP communication, 2 A @ 30 VAC / VDC SPDT relay, audible alarm, water / dust tight enclosure  LPT-B-TCO-R
Single channel, electrochemical chlorine (Cl2) sensor (0 - 5 ppm range), LCD display, BACnet® MS/TP communication, 2 A @ 30 VAC / VDC SPDT relay, audible alarm, water / dust tight enclosure  LPT-B-CL2
Single channel, electrochemical chlorine dioxide (ClO2) sensor (0 - 1.0 ppm range), LCD display, BACnet® MS/TP communication, 2 A @ 30 VAC / VDC SPDT relay, audible alarm, water / dust tight enclosure  LPT-B-CLO2
Single channel, electrochemical ethylene (C2H4) sensor (0 - 200 ppm range), LCD display, BACnet® MS/TP communication, 2 A @ 30 VAC / VDC SPDT relay, audible alarm, water / dust tight enclosure  LPT-B-C2H4
Single channel, electrochemical ethylene oxide (C2H4O) sensor (0 - 20 ppm range), LCD display, BACnet® MS/TP communication, 2 A @ 30 VAC / VDC SPDT relay, audible alarm, water / dust tight enclosure  LPT-B-EETO
Single channel, electrochemical fluorine (F2) sensor (0 - 1 ppm range), LCD display, BACnet® MS/TP communication, 2 A @ 30 VAC / VDC SPDT relay, audible alarm, water / dust tight enclosure  LPT-B-F2
Single channel, electrochemical formaldehyde (HCHO / CH2O) sensor (0 - 5 ppm range), LCD display, BACnet® MS/TP communication, 2 A @ 30 VAC / VDC SPDT relay, audible alarm, water / dust tight enclosure  LPT-B-CH2O
Single channel, electrochemical hydrogen sulphide (H2S) sensor (0 - 50 ppm range), LCD display, BACnet® MS/TP communication, 2 A @ 30 VAC / VDC SPDT relay, audible alarm, water / dust tight enclosure  LPT-B-EH2
Single channel, electrochemical oxygen (O2) sensor (0 - 25% volume range), LCD display, BACnet® MS/TP communication, 2 A @ 30 VAC / VDC SPDT relay, audible alarm, water / dust tight enclosure  LPT-B-O2
Single channel, electrochemical hydrogen sulphide (H2S) sensor (0 - 50 ppm range), LCD display, BACnet® MS/TP communication, 2 A @ 30 VAC / VDC SPDT relay, audible alarm, water / dust tight enclosure  LPT-B-H2SB
Single channel, electrochemical hydrogen chloride (HCL) sensor (0 - 20 ppm range), LCD display, BACnet® MS/TP communication, 2 A @ 30 VAC / VDC SPDT relay, audible alarm, water / dust tight enclosure  LPT-B-HCL
Single channel, electrochemical hydrogen cyanide (HCN) sensor (0 - 100 ppm range), LCD display, BACnet® MS/TP communication, 2 A @ 30 VAC / VDC SPDT relay, audible alarm, water / dust tight enclosure  LPT-B-HCN
Single channel, electrochemical hydrogen fluoride (HF) sensor (0 – 10.0 ppm range), LCD display, BACnet® MS/TP communication, 2 A @ 30 VAC / VDC SPDT relay, audible alarm, water / dust tight enclosure  LPT-B-HF
Single channel, electrochemical nitric oxide (NO) sensor (0 - 100 ppm range), LCD display, BACnet® MS/TP communication, 2 A @ 30 VAC / VDC SPDT relay, audible alarm, water / dust tight enclosure  LPT-B-NO
Single channel, internal electrochemical 3-year nitrogen dioxide (NO2) sensor (0 - 10 ppm range), LCD display, BACnet® MS/TP communication, 2 A @ 30 VAC / VDC SPDT relay, audible alarm, water / dust tight enclosure  LPT-B-NO2A
Single channel, internal electrochemical 6-year nitrogen dioxide (NO2) sensor (0 - 10 ppm range), LCD display, BACnet® MS/TP communication, 2 A @ 30 VAC / VDC SPDT relay, audible alarm, water / dust tight enclosure  LPT-B-NO2B
Dual channel, internal electrochemical 6-year nitrogen dioxide (NO2) sensor (0 - 10 ppm), must add ESH-A remote sensor, LCD display, BACnet® MS/TP communication, 2 A @ 30 VAC / VDC SPDT relay, audible alarm, water / dust tight enclosure  LPT-B-NO2B-R
Single channel, electrochemical ozone (O3) sensor (0 - 2 ppm range), LCD display, BACnet® MS/TP communication, 2 A @ 30 VAC / VDC SPDT relay, audible alarm, water / dust tight enclosure  LPT-B-O3
Single channel, electrochemical phosphine (PH3) sensor (0 - 5 ppm range), LCD display, BACnet® MS/TP communication, 2 A @ 30 VAC / VDC SPDT relay, audible alarm, water / dust tight enclosure  LPT-B-PH3
LPT-B-SIH4 Single channel, electrochemical silane (SiH4) sensor (0 - 20 ppm range), LCD display, BACnet® MS/TP communication, 2 A @ 30 VAC / VDC SPDT relay, audible alarm, water / dust tight enclosure  LPT-B-SIH4
Single channel, electrochemical sulphur dioxide (SO2) sensor (0 - 20 ppm range), LCD display, BACnet® MS/TP communication, 2 A @ 30 VAC / VDC SPDT relay, audible alarm, water / dust tight enclosure  LPT-B-SO2
Dual channel, internal electrochemical 6-year carbon monoxide (CO) sensor (0 - 200 ppm range) and internal electrochemical 6-year nitrogen dioxide (NO2) sensor (0 - 10 ppm), LCD display, BACnet® MS/TP communication, 2 A @ 30 VAC / VDC SPDT relay, audible alarm, water / dust tight enclosure  LPT-B-TCO-NO2B
Three channel, internal electrochemical 6-year carbon monoxide (CO) sensor (0 - 200 ppm range) and internal electrochemical 6-year nitrogen dioxide (NO2) sensor (0 - 10 ppm), must add ESH-A remote sensor, LCD display, BACnet® MS/TP communication, 2 A @ 30 VAC / VDC SPDT relay, audible alarm, water / dust tight enclosure  LPT-B-TCO-NO2B-R

Options

Description Code
Internal heater for cold environment applications down to -40°C / -40°F  H
Splash guard, factory installed, IP54 rating, not available with Cl2, HCl or O3 (sticky gas) sensors  S

Remote Sensors

Description Code
Catalytic Hydrogen (H2) ESH-A Remote Sensor (0 - 100% LEL), water / dust tight enclosure  ESH-A-CH2-100
Catalytic Methane (CH4) ESH-A Remote Sensor (0 - 100% LEL), water / dust tight enclosure  ESH-A-CCH4-100
Catalytic Propane (C3H8) ESH-A Remote Sensor (0 - 100% LEL), water / dust tight enclosure  ESH-A-CC3H8-100
Solid state refrigerant (R22) ESH-A Remote Sensor (0 - 2,000 ppm range), water / dust tight enclosure  ESH-A-SR22
Solid state refrigerant (R134A) ESH-A Remote Sensor (0 - 2,000 ppm range), water / dust tight enclosure  ESH-A-SR134A
Solid state refrigerant (R402A) ESH-A Remote Sensor (0 - 2,000 ppm range), water / dust tight enclosure  ESH-A-SR402A
Solid state refrigerant (R404A) ESH-A Remote Sensor (0 - 2,000 ppm range), water / dust tight enclosure  ESH-A-SR404A
Solid state refrigerant (R407C) ESH-A Remote Sensor (0 - 2,000 ppm range), water / dust tight enclosure  ESH-A-SR407C
Solid state refrigerant (R410A) ESH-A Remote Sensor (0 - 2,000 ppm range), water / dust tight enclosure  ESH-A-SR410A
Solid state refrigerant (R422D) ESH-A Remote Sensor (0 - 2,000 ppm range), water / dust tight enclosure  ESH-A-SR422D
Solid state refrigerant (R438A) ESH-A Remote Sensor (0 - 2,000 ppm range), water / dust tight enclosure  ESH-A-SR438A
Solid state refrigerant (R507) ESH-A Remote Sensor (0 - 2,000 ppm range), water / dust tight enclosure  ESH-A-SR507A
Solid state TVOC ESH-A Remote Sensor (0 - 500 ppm range), water / dust tight enclosure  ESH-A-STVOC
TVOC PID ESH-A Remote Sensor (0 - 30 ppm range), water / dust tight enclosure  ESH-A-SPL
TVOC PID ESH-A Remote Sensor (0 - 300 ppm range), water / dust tight enclosure  ESH-A-SPH

CAL 2000 LT Calibration System

» Hand held, easy to use
» Up to 10 hours of gas source use
» User defined gas concentration and flow rate outputs
» Traceable to NIST standards and rated for use in hazardous areas

Metal Protective Guard

» 16 gauge, clear anodized metal protective guard
» Larger size for controllers & self-contained systems
» Smaller size for analog & digital transmitters

Calibration Kit

» Commonly used tools required for calibration in one convenient toolbox
 

GENie Calibration Systems

» Hand held, rugged design
» User adjustable gas concentration outputs
» Disposable gas vials do not expire and are non-hazardous for transport
» Traceable to NIST standards
 

Remote Strobe Light

» Low profile, lightweight
» Weather and corrosion resistant
» Surface mount and 1/2” NPT conduit mount

Remote Industrial Horn

» Corrosion resistant finish
» Volume adjustable
» Low current, high decibel

RSH-24VDC Remote Strobe & Horn Combo (with Enclosure)

» Two alarm features combined into one device
» Light weight, weather and corrosion resistant
» Independent settings for horn, strobe or horn and strobe together
» Surface mount and 1/2” NPT conduit mount
» ABS / Polycarbonate water / dust tight enclosure

Remote Audible Alarm

» Loud remote audible alarm
» Easy installation
» 2-wire VDC
» Standard corrosion resistant enclosure
» Water tight option available for wet or wash down environments

Magnetic Wand

» Used for non-intrusive calibration of the LPT-A and SCC
» Use to access menu options and initiate non-intrusive calibration for the LPT-M, LPT-P, LPT-B, DCC and CXT
 

Bump Test Systems

» Hand held, easy to use
» Disposable gas generating cells do not expire
» Non-hazardous shipping (not a dangerous good)


Bookmark and Share

Contact Us

General Inquiry
Application Support
Quote Request
Maintenance Support
Technical Support
RMA Request
  Warranty