Bump Test Systems

    Key Features

  • » 
    Hand held, easy to use
  • » 
    Disposable gas generating cells do not expire
  • » 
    Non-hazardous shipping (not a dangerous good)

Bump tests provide an easy and quick way of checking the performance of gas detectors. Bump tests should be done monthly as needed or required by law. If the bump test fails, a full calibration should be done.

The QC-50 Bump Test System is a hand pump system that allows a test concentration of gas to flow over the detector's sensor. This device uses unique QuickCheck Vials (QCV) that have a small amount of the target gas in a liquid form, sealed in an inner ampoule. Breaking the inner ampoule allows the liquid to absorb into a filter which then diffuses out the gas. Ideal for bump testing Ammonia, Hexane, Hydrogen Chloride or Toulene gas detectors.

The QC-100 Bump Test System is similar to the QC-50 but is powered by two AA batteries to motorize a pump that provides continuous output of calibration gas. The needle valve allows users to adjust the amount of gas being generated to check the gas detection device for higher accuracy.

The MiniBump Test System is an ultra small, battery powered gas generator specifically designed for bump testing Chlorine, Hydrogen, Hydrogen cyanide and Hydrogen sulphide gas sensors. It is approved intrinsically safe.

SCC Product Overview Video

Gas Types

----------------------------------------------------------------------------------------------------------------------------------------------------------------
QC-50 and QC-100 Gas Types (QCV Vials)
----------------------------------------------------------------------------------------------------------------------------------------------------------------
Ammonia (NH3)
Hexane (C6H14)
Hydrogen chloride (HCI)
Toluene (C7H8)
Dimensions: 8.2 cm x 0.9 cm (3.23 in x 0.35 in)
Weight: 2.4 g (0.08 oz)
Quantity: 12 vials per pack
Useful Vial Life: approximately 8 hours
----------------------------------------------------------------------------------------------------------------------------------------------------------------
MiniBump Gas Types
----------------------------------------------------------------------------------------------------------------------------------------------------------------
Chlorine (Cl2)
Hydrogen (H2)
Hydrogen cyanide (HCN)
Hydrogen sulphide (H2S)
Quantity: 1000 bump tests

Sensors

Mechanical

QC-50 Bump Tester  
Weight: 49 g (1.73 oz)
Size:
15.3 x 5 cm (6 x 2 in)
   
QC-100 Bump Tester  
Weight: 220 g (7.8 oz)
Size:
15.2 x 5.8 x 3.0 cm (6 x 2.2 x 1.1 in)
   
MiniBump Test System  
Weight: 220 g (0.5 lb)
Size:
6 cm W x  10.4 cm H x  3 cm D
(2.36”  W x 3.88” H x 1.18” D)

Electrical

QC-50 Bump Tester  
Power: Hand pump of aspirated bulb
   
QC-100 Bump Tester  
Power: Two alkaline AA batteries
Battery Life: approximately 10 hours
   
MiniBump Test System  
Power: Two alkaline AA batteries
Battery Life:
approximately 10 hours

Input / Output

User Interface

Environmental

Operating Temperature: 5°C to 50°C (41°F to 122°F)
Humidity: 0 - 100% RH non-condensing

Certifications

QC-100 Bump Tester  
CE
   
MiniBump Test System  
Conforms to: EC Directive 89/336/EEC in accordance with the provisions of Statutory Instrument 2372
Conforms to: EN 50081-1 and EN 50082-1
Intrinsically Safe: Class 1, Division 1, Groups A, B, C, D
CSA NRTL/C Exia T-6 approved intrinsically safe with CE mark

 

Calibration gas generation method is approved under the ISO DIS 6145-11 standards

More Brochures

Product Specifications

Application Brochures

Drawings

Software

Sensor Specification

Engineering Specification Samples

DataSheets

Operation Manual

Part Numbers

Description Code
Bump Tester with hand pump operation, includes 1.5 m long x 4.76 mm OD (5 ft x 3/16 in OD) hose and manual (does not include gas)  QC-50
Bump Tester Kit, hand pump operation, includes belt pack, 1.5 m long x 4.76 mm OD (5 ft x 3/16 in OD) hose, manual and one 12 pack gas source (please specify QCV gas)  QC-50-KIT
Bump Tester with battery operation, includes batteries, 1.5 m long x 4.76 mm OD (5 ft x 3/16 in OD) hose and manual, (does not include gas)  QC-100
Bump Tester Kit, battery operation, includes belt pack, batteries, 1.5 m long x 4.76 mm OD (5 ft x 3/16 in OD) hose, manual and one 12 pack gas source (please specify QCV gas)  QC-100-KIT
Ammonia (NH3) gas source for QC-50 and QC-100, 12 pack, up to 8 consecutive hours of use  QCV-NH3
Hexane (C6H14) gas source for QC-50 and QC-100, 12 pack, up to 8 consecutive hours of use  QCV-C6H14
Hydrogen chloride (HCI) gas source for QC-50 and QC-100, 12 pack, up to 8 consecutive hours of use  QCV-HCI
Toulene (C7H8) gas source for QC-50 and QC-100, 12 pack, up to 8 consecutive hours of use  QCV-C7H8
MiniBump Test System includes wall mount housing, batteries, 1.5 m long x 4.76 mm OD (5 ft x 3/16 in OD) hose, rubber calibration cup and manual, provides up to 1000 tests, Does not include gas source.  MB-TEST
Chlorine (CL2) gas source for MiniBump, approx. 5ppm output  MB-CL2
Hydrogen (H2) gas source for MiniBump, approx. 25 ppm output  MB-H2
Hydrogen sulphide (H2S) gas source for MiniBump, approx. 25 ppm output  MB-H2S
Hydrogen cyanide (HCN) gas source for MiniBump, approx. 10 ppm output  MB-HCN

Bookmark and Share

Contact Us

General Inquiry
Application Support
Quote Request
Maintenance Support
Technical Support
RMA Request
  Warranty
Distribution Opportunity