AST Analog Transmitter

    Key Features

  • » 
    4 - 20 mA or 0 - 10 VDC linear output signal
  • » 
    LED indicators for power and open loop
  • » 
    RoHS compliant circuit boards
  • » 
    Temperature compensation
  • » 
    Automatic thermal resetting fuse
  • » 
    Automated calibration procedure
  • » 
    C-Tick certified

The rugged, reliable AST analog transmitter offers a variety of sensor types to detect a wide range of gases, including solid state, electrochemical, catalytic, infrared, and PID.

AST transmitters convert the raw signal from a sensor into a useful output that can be sent to a controller or building automation system.

Several enclosure options are available to meet the requirements of many different applications.

AST transmitters feature 4 - 20 mA or 0 - 10 VDC linear output signals, automatic thermal resetting fuse, RoHS compliant circuit boards, and LED indicators for power and open loop. Options include a field settable dry contact relay and a local digital display.

Automated calibration and other maintenance procedures are simple and are easily performed in the field.

APPLICATIONS

  • » 
    Parking Garages
  • » 
    Pools
  • » 
    Repair Shops
  • » 
    Hotels
  • » 
    Ice Cleaning Machine Rooms
  • » 
    Manufacturing Plants
  • » 
    many more

Gas Types

Ammonia (NH3) EAM
Carbon Monoxide (CO) ECO
Combustible Gases (solid state or catalytic) SCB or CCB
Chlorine (Cl2) ECL
Ethylene (C2H4) EC4
Formaldehyde (HCHO) EFO
Hydrogen (H2) EH2
Hydrogen Sulphide (H2S) EHS
Methane (CH4) SCB
Nitrogen Dioxide (NO2) END
Nitric Oxide (NO) ENO
Oxygen (O2) OO2
Ozone (O3) EO3
Propane (C3H8) SCB
Refrigerants (R12, R22, R134A, R401A, R402A, R404A, R407C, R410A, R422A, R422D, R438A, R507) SR2
Sulphur Dioxide (SO2) ESO
TVOCs (solid state or PID) SOS, SPL or SPH

Sensors


Mechanical

AST Standard Analog Transmitter
Enclosure: Polycarbonate
Weight: 255 g (9 oz)
Size: 4.4" x 6.5" x 2.5" (113 mm x 165 mm x 65 mm)
   
AST-W Watertight Analog Transmitter
Enclosure: Watertight Polycarbonate
Weight: 340 g (12 oz)
Size: 5.05” x 5.05” x 3.05” (129 mm x 129 mm x 77 mm)

Electrical

Power Requirement: 12 - 30 VAC or 16 - 30 VDC
Current Draw: Approximately 80 - 120 mA
Outputs: Linear 4 - 20 mA or 0 - 10 VDC signal, jumper selectable
Wiring: VDC three-conductor shielded; VAC four-conductor shielded
Fuse: Automatic resetting thermal

Environmental

Operating Temperature: -20°C to 40°C (-4°F to 104°F)
Humidity: 15 - 95% RH non-condensing

Note: Measurements above are sensor dependent.

Certifications

C-Tick Certification C-Tick Certified

Drawings

Product Specifications

Engineering Specification Samples

DataSheets

Operation Manual

Application Brochure

Quick Application Guide
Quick Application Guide For Fixed Gas Detection SystemsFor Fixed Gas Detection Systems

Hotel Application Brochures
Hotel Application BrochureAir Conditioned Hotel Room Application

Miscellaneous Files

AST Standard Analog Transmitter

Ammonia (NH3) electrochemical, 0-500 ppm AST-EAM
Carbon monoxide (CO), 0-200 ppm AST-ECO
Combustible gases (solid state), 0-50% LEL AST-SCB
Combustible gases (catalytic), 0-100% LEL AST-CCB
Chlorine (Cl2), 0-5 ppm AST-ECL
Ethylene (C2H4), 0-2000 ppm AST-EC4
Formaldehyde (HCHO), 0-10 ppm AST-EFO
Hydrogen (H2), 0-2000 ppm AST-EH2
Hydrogen sulphide (H2S), 0-50 ppm AST-EHS
Methane (CH4), 0 - 50% LEL AST-SCB
Nitrogen dioxide (NO2), 0-10 ppm AST-END
Nitric oxide (NO), 0-100 ppm AST-ENO
Oxygen (O2) electrochemical, 0-25% volume AST-OO2
Ozone (O3), 0-2 ppm AST-EO3
Propane (C3H8), 0 - 50% LEL AST-SCB
Refrigerants (R12, R22, R134A, R401A, R402A, R404A, R407C, R410A, R422A, R422D, R438A, R507), 0-2000 ppm AST-SR2
Sulphur dioxide (SO2), 0-20 ppm AST-ESO
TVOCs (solid state), 0-500 ppm AST-SOS
TVOCs (PID), 0-50 ppm AST-SPL
TVOCs (PID), 0-300 ppm AST-SPH

Standard Option

Local LED digitial display N
Relay, dry contact S.P.D.T., 2 amps @ 28 V R
Remote sensor Z

AST-W Watertight Analog Transmitter

Ammonia (NH3) electrochemical, 0-500 ppm AST-EAM-W
Carbon monoxide (CO), 0-200 ppm AST-ECO-W
Combustible gases (solid state), 0-50% LEL AST-SCB-W
Combustible gases (catalytic), 0-100% LEL AST-CCB-W
Chlorine (Cl2), 0-5 ppm AST-ECL-W
Ethylene (C2H4), 0-2000 ppm AST-EC4-W
Formaldehyde (HCHO), 0-10 ppm AST-EFO-W
Hydrogen (H2), 0-2000 ppm AST-EH2-W
Hydrogen sulphide (H2S), 0-50 ppm AST-EHS-W
Methane (CH4), 0 - 50% LEL AST-SCB-W
Nitrogen dioxide (NO2), 0-10 ppm AST-END-W
Nitric oxide (NO), 0-100 ppm AST-ENO-W
Oxygen (O2) electrochemical, 0-25% volume AST-OO2-W
Sulphur dioxide (SO2), 0-20 ppm AST-ESO-W
Ozone (O3), 0-2 ppm AST-EO3-W
Propane (C3H8), 0 - 50% LEL AST-SCB-W
Refrigerants (R12, R22, R134A, R401A, R402A, R404A, R407C, R410A, R422A, R422D, R438A, R507), 0-2000 ppm AST-SR2-W
TVOCs (solid state), 0-500 ppm AST-SOS-W
TVOCs (PID), 0-50 ppm AST-SPL-W
TVOCs (PID), 0-300 ppm AST-SPH-W

Watertight Option

Local LED digitial display N
Relay, dry contact S.P.D.T., 2 amps @ 28 V R
Splash guard S

Metal Protective Guard

» 16 guage, clear anodized metal protective guard
» Larger size for controllers & self-contained systems
» Smaller size for analog & digital transmitters

Fixed Calibration Kit

» Full selection of calibration gases from stock
» All required calibration accessories for field and shop calibration
» Full service and calibration shop for fixed gas detection instruments


Bookmark and Share

Contact Us

General Inquiry
Application Support
Quote Request
Maintenance Support
Technical Support
RMA Request
  Warranty
Distribution Opportunity