Key Features
- »
4 - 20 mA or 0 - 10 VDC linear output signal
- »
LED indicators for power and open loop
- »
RoHS compliant circuit boards
- »
Temperature compensation
- »
Automatic thermal resetting fuse
- »
Automated calibration procedure
- »
C-Tick certified
|
The rugged, reliable AST analog transmitter offers a variety of sensor types to detect a wide range of gases, including solid state, electrochemical, catalytic, infrared, and PID.
AST transmitters convert the raw signal from a sensor into a useful output that can be sent to a controller or building automation system.
Several enclosure options are available to meet the requirements of many different applications.
AST transmitters feature 4 - 20 mA or 0 - 10 VDC linear output signals, automatic thermal resetting fuse, RoHS compliant circuit boards, and LED indicators for power and open loop. Options include a field settable dry contact relay and a local digital display.
Automated calibration and other maintenance procedures are simple and are easily performed in the field.
Gas Types
| Ammonia (NH3) |
EAM |
| Carbon Monoxide (CO) |
ECO |
| Combustible Gases (solid state or catalytic) |
SCB or CCB |
| Chlorine (Cl2) |
ECL |
| Ethylene (C2H4) |
EC4 |
| Formaldehyde (HCHO) |
EFO |
| Hydrogen (H2) |
EH2 |
| Hydrogen Sulphide (H2S) |
EHS |
| Methane (CH4) |
SCB |
| Nitrogen Dioxide (NO2) |
END |
| Nitric Oxide (NO) |
ENO |
| Oxygen (O2) |
OO2 |
| Ozone (O3) |
EO3 |
| Propane (C3H8) |
SCB |
| Refrigerants (R22, R134A, R401A, R402A, R404A, R407C, R410A, R422A, R422D, R438A, R507) |
SR2 |
| Sulphur Dioxide (SO2) |
ESO |
| TVOCs (solid state or PID) |
SOS, SPL or SPH |
Sensors
Mechanical
|
AST Standard Analog Transmitter |
|
Enclosure: |
Polycarbonate |
|
Weight: |
255 g (9 oz) |
|
Size: |
4.4" x 6.5" x 2.5" (113 mm x 165 mm x 65 mm) |
|
AST-W Watertight Analog Transmitter |
|
Enclosure: |
Watertight Polycarbonate |
|
Weight: |
340 g (12 oz) |
|
Size: |
5.05” x 5.05” x 3.05” (129 mm x 129 mm x 77 mm) |
Electrical
|
Power Requirement: |
12 - 30 VAC or 16 - 30 VDC |
|
Current Draw: |
Approximately 80 - 120 mA |
|
Outputs: |
Linear 4 - 20 mA or 0 - 10 VDC signal, jumper selectable |
|
Wiring: |
VDC three-conductor shielded; VAC four-conductor shielded |
|
Fuse: |
Automatic resetting thermal |
Input / Output
User Interface
Environmental
|
Operating Temperature: |
-20°C to 40°C (-4°F to 104°F) |
|
Humidity: |
15 - 95% RH non-condensing |
Note: Measurements above are sensor dependent.
Certifications
 |
C-Tick Certified |
Drawings
Product Specification
Sensor Specification
Engineering Specification Samples
DataSheets
Operation Manual
Application Brochure
Miscellaneous Files
AST Standard Analog Transmitter
| Description |
Code |
| Electrochemical ammonia (NH3) sensor (0 - 500 ppm range), LED indicators, 4 - 20 mA or 0 - 10 VDC output, 12 - 30 VAC or 16 - 30 VDC |
AST-EAM |
| Electrochemical carbon monoxide (CO) sensor (0 - 200 ppm range), LED indicators, 4 - 20 mA or 0 - 10 VDC output, 12 - 30 VAC or 16 - 30 VDC |
AST-ECO |
| Catalytic combustible gas (pls specify) sensor (0 - 100% LEL range), LED indicators, 4 - 20 mA or 0 - 10 VDC output, 12 - 30 VAC or 16 - 30 VDC |
AST-CCB |
| Solid state combustible gas (pls specify) sensor (0 - 50% LEL range), LED indicators, 4 - 20 mA or 0 - 10 VDC output, 12 - 30 VAC or 16 - 30 VDC |
AST-SCB |
| Electrochemical ethylene (C2H4) sensor (0 - 2,000 ppm range), LED indicators, 4 - 20 mA or 0 - 10 VDC output, 12 - 30 VAC or 16 - 30 VDC |
AST-EC4 |
| Electrochemical formaldehyde (CH2O) sensor (0 - 10 ppm range), LED indicators, 4 - 20 mA or 0 - 10 VDC output, 12 - 30 VAC or 16 - 30 VDC |
AST-EFO |
| Electrochemical hydrogen (H2) sensor (0 - 2,000 ppm range), LED indicators, 4 - 20 mA or 0 - 10 VDC output, 12 - 30 VAC or 16 - 30 VDC |
AST-EH2 |
| Catalytic hydrogen (H2) sensor (0 - 100% LEL range), LED indicators, 4 - 20 mA or 0 - 10 VDC output, 12 - 30 VAC or 16 - 30 VDC |
AST-CCB |
| Solid state hydrogen (H2) sensor (0 - 50% LEL range), LED indicators, 4 - 20 mA or 0 - 10 VDC output, 12 - 30 VAC or 16 - 30 VDC |
AST-SCB |
| Catalytic methane (CH4) sensor (0 - 100% LEL range), LED indicators, 4 - 20 mA or 0 - 10 VDC output, 12 - 30 VAC or 16 - 30 VDC |
AST-CCB |
| Solid state methane (CH4) sensor (0 - 50% LEL range), LED indicators, 4 - 20 mA or 0 - 10 VDC output, 12 - 30 VAC or 16 - 30 VDC |
AST-SCB |
| Electrochemical nitric oxide (NO) sensor (0 - 100 ppm range), LED indicators, 4 - 20 mA or 0 - 10 VDC output, 12 - 30 VAC or 16 - 30 VDC |
AST-ENO |
| Electrochemical nitrogen dioxide (NO2) sensor (0 - 10 ppm range), LED indicators, 4 - 20 mA or 0 - 10 VDC output, 12 - 30 VAC or 16 - 30 VDC |
AST-END |
| Electrochemical oxygen (O2) sensor (0 - 25% volume range), LED indicators, 4 - 20 mA or 0 - 10 VDC output, 12 - 30 VAC or 16 - 30 VDC |
AST-OO2 |
| Catalytic propane (C3H8) sensor (0 - 100% LEL range), LED indicators, 4 - 20 mA or 0 - 10 VDC output, 12 - 30 VAC or 16 - 30 VDC |
AST-CCB |
| Solid state propane (C3H8) sensor (0 - 50% LEL range), LED indicators, 4 - 20 mA or 0 - 10 VDC output, 12 - 30 VAC or 16 - 30 VDC |
AST-SCB |
| Solid state refrigerant (R134A) sensor (0 - 2,000 ppm range), LED indicators, 4 - 20 mA or 0 - 10 VDC output, 12 - 30 VAC or 16 - 30 VDC |
AST-SR2 |
| Solid state refrigerant (R22) sensor (0 - 2,000 ppm range), LED indicators, 4 - 20 mA or 0 - 10 VDC output, 12 - 30 VAC or 16 - 30 VDC |
AST-SR2 |
| Solid state refrigerant (R402A) sensor (0 - 2,000 ppm range), LED indicators, 4 - 20 mA or 0 - 10 VDC output, 12 - 30 VAC or 16 - 30 VDC |
AST-SR2 |
| Solid state refrigerant (R404A) sensor (0 - 2,000 ppm range), LED indicators, 4 - 20 mA or 0 - 10 VDC output, 12 - 30 VAC or 16 - 30 VDC |
AST-SR2 |
| Solid state refrigerant (R407C) sensor (0 - 2,000 ppm range), LED indicators, 4 - 20 mA or 0 - 10 VDC output, 12 - 30 VAC or 16 - 30 VDC |
AST-SR2 |
| Solid state refrigerant (R410A) sensor (0 - 2,000 ppm range), LED indicators, 4 - 20 mA or 0 - 10 VDC output, 12 - 30 VAC or 16 - 30 VDC |
AST-SR2 |
| Solid state refrigerant (R422A) sensor (0 - 2,000 ppm range), LED indicators, 4 - 20 mA or 0 - 10 VDC output, 12 - 30 VAC or 16 - 30 VDC |
AST-SR2 |
| Solid state refrigerant (R422D) sensor (0 - 2,000 ppm range), LED indicators, 4 - 20 mA or 0 - 10 VDC output, 12 - 30 VAC or 16 - 30 VDC |
AST-SR2 |
| Solid state refrigerant (R507) sensor (0 - 2,000 ppm range), LED indicators, 4 - 20 mA or 0 - 10 VDC output, 12 - 30 VAC or 16 - 30 VDC |
AST-SR2 |
| Solid state TVOC sensor (0 - 500 ppm range), LED indicators, 4 - 20 mA or 0 - 10 VDC output, 12 - 30 VAC or 16 - 30 VDC |
AST-SOS |
| PID TVOCs sensor (0 - 300 ppm range), LED indicators, 4 - 20 mA or 0 - 10 VDC output, 12 - 30 VAC or 16 - 30 VDC |
AST-SPH |
| PID TVOCs sensor (0 - 30 ppm range), LED indicators, 4 - 20 mA or 0 - 10 VDC output, 12 - 30 VAC or 16 - 30 VDC |
AST-SPL |
Standard Option
| Description |
Code |
| LED digital display |
N |
| Relay, dry contact SPDT, 2 amps @ 28 V |
R |
| Remote sensor |
Z |
| Water / dust tight enclosure |
W |
| Splash guard (for water / dust tight enclosure only) |
S |
AST-W Watertight Analog Transmitter
| Description |
Code |
| Electrochemical ammonia (NH3) sensor (0 - 500 ppm range), LED indicators, 4 - 20 mA or 0 - 10 VDC output, 12 - 30 VAC or 16 - 30 VDC, water / dust tight enclosure |
AST-EAM-W |
| Electrochemical carbon monoxide (CO) sensor (0 - 200 ppm range), LED indicators, 4 - 20 mA or 0 - 10 VDC output, 12 - 30 VAC or 16 - 30 VDC, water / dust tight enclosure |
AST-ECO-W |
| Electrochemical chlorine (Cl2) sensor (0 - 5 ppm range), LED indicators, 4 - 20 mA or 0 - 10 VDC output, 12 - 30 VAC or 16 - 30 VDC, water / dust tight enclosure |
AST-ECL-W |
| Catalytic combustible gas (pls specify) sensor (0 - 100% LEL range), LED indicators, 4 - 20 mA or 0 - 10 VDC output, 12 - 30 VAC or 16 - 30 VDC, water / dust tight enclosure |
AST-CCB-W |
| Solid state combustible gas (pls specify) sensor (0 - 50% LEL range), LED indicators, 4 - 20 mA or 0 - 10 VDC output, 12 - 30 VAC or 16 - 30 VDC, water / dust tight enclosure |
AST-SCB-W |
| Electrochemical ethylene (C2H4) sensor (0 - 2,000 ppm range), LED indicators, 4 - 20 mA or 0 - 10 VDC output, 12 - 30 VAC or 16 - 30 VDC, water / dust tight enclosure |
AST-EC4-W |
| Electrochemical ethylene oxide (C2H4O) sensor (0 - 20 ppm range), LED indicators, 4 - 20 mA or 0 - 10 VDC output, 12 - 30 VAC or 16 - 30 VDC, water / dust tight enclosure |
AST-EET-W |
| Electrochemical formaldehyde (CH2O) sensor (0 - 10 ppm range), LED indicators, 4 - 20 mA or 0 - 10 VDC output, 12 - 30 VAC or 16 - 30 VDC, water / dust tight enclosure |
AST-EFO-W |
| Electrochemical hydrogen (H2) sensor (0 - 2,000 ppm range), LED indicators, 4 - 20 mA or 0 - 10 VDC output, 12 - 30 VAC or 16 - 30 VDC, water / dust tight enclosure |
AST-EH2-W |
| Catalytic hydrogen (H2) sensor (0 - 100% LEL range), LED indicators, 4 - 20 mA or 0 - 10 VDC output, 12 - 30 VAC or 16 - 30 VDC, water / dust tight enclosure |
AST-CCB-W |
| Solid state hydrogen (H2) sensor (0 - 50% LEL range), LED indicators, 4 - 20 mA or 0 - 10 VDC output, 12 - 30 VAC or 16 - 30 VDC, water / dust tight enclosure |
AST-SCB-W |
| Electrochemical hydrogen sulphide (H2S) sensor (0 - 50 ppm range), LED indicators, 4 - 20 mA or 0 - 10 VDC output, 12 - 30 VAC or 16 - 30 VDC, water / dust tight enclosure |
AST-EHS-W |
| Catalytic methane (CH4) sensor (0 - 100% LEL range), LED indicators, 4 - 20 mA or 0 - 10 VDC output, 12 - 30 VAC or 16 - 30 VDC, water / dust tight enclosure |
AST-CCB-W |
| Solid state methane (CH4) sensor (0 - 50% LEL range), LED indicators, 4 - 20 mA or 0 - 10 VDC output, 12 - 30 VAC or 16 - 30 VDC, water / dust tight enclosure |
AST-SCB-W |
| Electrochemical nitric oxide (NO) sensor (0 - 100 ppm range), LED indicators, 4 - 20 mA or 0 - 10 VDC output, 12 - 30 VAC or 16 - 30 VDC, water / dust tight enclosure |
AST-ENO-W |
| Electrochemical nitrogen dioxide (NO2) sensor (0 - 10 ppm range), LED indicators, 4 - 20 mA or 0 - 10 VDC output, 12 - 30 VAC or 16 - 30 VDC, water / dust tight enclosure |
AST-END-W |
| Electrochemical oxygen (O2) sensor (0 - 25% volume range), LED indicators, 4 - 20 mA or 0 - 10 VDC output, 12 - 30 VAC or 16 - 30 VDC, water / dust tight enclosure |
AST-OO2-W |
| Electrochemical ozone (O3) sensor (0 - 2 ppm range), LED indicators, 4 - 20 mA or 0 - 10 VDC output, 12 - 30 VAC or 16 - 30 VDC, water / dust tight enclosure |
AST-EO3-W |
| Catalytic propane (C3H8) sensor (0 - 100% LEL range), LED indicators, 4 - 20 mA or 0 - 10 VDC output, 12 - 30 VAC or 16 - 30 VDC, water / dust tight enclosure |
AST-CCB-W |
| Solid state propane (C3H8) sensor (0 - 50% LEL range), LED indicators, 4 - 20 mA or 0 - 10 VDC output, 12 - 30 VAC or 16 - 30 VDC, water / dust tight enclosure |
AST-SCB-W |
| Solid state refrigerant (R134A) sensor (0 - 2,000 ppm range), LED indicators, 4 - 20 mA or 0 - 10 VDC output, 12 - 30 VAC or 16 - 30 VDC, water / dust tight enclosure |
AST-SR2-W |
| Solid state refrigerant (R22) sensor (0 - 2,000 ppm range), LED indicators, 4 - 20 mA or 0 - 10 VDC output, 12 - 30 VAC or 16 - 30 VDC, water / dust tight enclosure |
AST-SR2-W |
| Solid state refrigerant (R402A) sensor (0 - 2,000 ppm range), LED indicators, 4 - 20 mA or 0 - 10 VDC output, 12 - 30 VAC or 16 - 30 VDC, water / dust tight enclosure |
AST-SR2-W |
| Solid state refrigerant (R404A) sensor (0 - 2,000 ppm range), LED indicators, 4 - 20 mA or 0 - 10 VDC output, 12 - 30 VAC or 16 - 30 VDC, water / dust tight enclosure |
AST-SR2-W |
| Solid state refrigerant (R407C) sensor (0 - 2,000 ppm range), LED indicators, 4 - 20 mA or 0 - 10 VDC output, 12 - 30 VAC or 16 - 30 VDC, water / dust tight enclosure |
AST-SR2-W |
| Solid state refrigerant (R410A) sensor (0 - 2,000 ppm range), LED indicators, 4 - 20 mA or 0 - 10 VDC output, 12 - 30 VAC or 16 - 30 VDC, water / dust tight enclosure |
AST-SR2-W |
| Solid state refrigerant (R422A) sensor (0 - 2,000 ppm range), LED indicators, 4 - 20 mA or 0 - 10 VDC output, 12 - 30 VAC or 16 - 30 VDC, water / dust tight enclosure |
AST-SR2-W |
| Solid state refrigerant (R422D) sensor (0 - 2,000 ppm range), LED indicators, 4 - 20 mA or 0 - 10 VDC output, 12 - 30 VAC or 16 - 30 VDC, water / dust tight enclosure |
AST-SR2-W |
| Solid state refrigerant (R507) sensor (0 - 2,000 ppm range), LED indicators, 4 - 20 mA or 0 - 10 VDC output, 12 - 30 VAC or 16 - 30 VDC, water / dust tight enclosure |
AST-SR2-W |
| Electrochemical sulphur dioxide (SO2) sensor (0 - 20 ppm range), LED indicators, 4 - 20 mA or 0 - 10 VDC output, 12 - 30 VAC or 16 - 30 VDC, water / dust tight enclosure |
AST-ESO-W |
| Solid state TVOC sensor (0 - 500 ppm range), LED indicators, 4 - 20 mA or 0 - 10 VDC output, 12 - 30 VAC or 16 - 30 VDC, water / dust tight enclosure |
AST-SOS-W |
| PID TVOCs sensor (0 - 300 ppm range), LED indicators, 4 - 20 mA or 0 - 10 VDC output, 12 - 30 VAC or 16 - 30 VDC, water / dust tight enclosure |
AST-SPH-W |
| PID TVOCs sensor (0 - 30 ppm range), LED indicators, 4 - 20 mA or 0 - 10 VDC output, 12 - 30 VAC or 16 - 30 VDC, water / dust tight enclosure |
AST-SPL-W |
Watertight Option
| Description |
Code |
| LED digital display |
N |
| Relay, dry contact SPDT, 2 amps @ 28 V |
R |
| Remote sensor |
Z |
| Splash guard |
S |
 |
Metal Protective Guard
» 16 gauge, clear anodized metal protective guard
» Larger size for controllers & self-contained systems
» Smaller size for analog & digital transmitters
|
 |
Calibration Kit
» Complete calibration kits
» All required calibration accessories for field and shop calibration
» Full selection of calibration gases from stock
|
 |
Sample Draw Pump Unit
» Self contained sample draw pump unit
» 24 VDC or VAC powered
» Standard water / dust tight enclosure
|
|
|
|