Fixed Gas Detectors
Controllers

FCS Flexible Control System

» Up to 128 channels of gas readings
» Works with analog and/or digital transmitters
» Full colour LCD touch screen display with LED indicators
» Door mounted audible alarm

QCC Quad Channel Controller

» Up to four channels of gas readings
» Works with analog and/or digital transmitters
» Four line LCD display with LED indicators
» Door mounted audible alarm

DCC Dual Channel Controller

» Single or dual channel operation
» Flexible internal and remote sensor configurations
» LCD display, LED indicators & audible alarm
» Password protected menu system
» Two 4-20 mA outputs for VFD control

SCC Self Contained Controller

» Single or dual channel
» Internal and remote sensor options
» Two 5-amp SPDT dry contact relays
» LED indicators & audible alarm

DCC-MRI Oxygen Sampling System

» Continuous monitoring of Oxygen level in rooms where compressed gases/cryogenic liquds are used
» 24 VDC power (nominal), LCD display with LED indicators
» Loud buzzer, blocked flow alarm, adjustable flow meter

DCC-SD Sample Draw System

» Continuous monitoring of gas hazards in hard to accessand restrictive locations
» Single toxic, combustible or refrigerant sensor options
» Loud buzzer, blocked flow alarm, adjustable flow meter

Transmitters

ART Infrared Refrigerant Transmitter

» Long life, non-dispersive infrared refrigerant sensor allows for accurate,     
   low level leak detection with no cross interferences from other gases
» Configurable to detect a specific refrigerant gas or groups of several refrigerants 
» Modbus RTU interface to connect to BAS/BMS systems
 

AST-I Industrial Infrared Transmitters

» Low power consumption
» Dual temperature compensated pyroelectric infrared sensors
» Fast response with accurate low-level gas detection

AST-IS Standard CO2 Transmitters

» Linear 4 - 20 mA or 0 - 10 VDC output
» Operating power 24 VDC or 24 VAC nominal
» Low maintenance, easy calibration

AST-IS Industrial CO2 Transmitters

» Linear 4 - 20 mA or 0 - 10 VDC output
» Operating power 24 VDC or 24 VAC nominal
» Low maintenance, easy calibration

CXT Explosion Proof Transmitter

» Large graphic LCD display for real time monitoring
» Menu driven magnetic keypad for user configurations
» Displays values in bar graphs or 30 minute onboard data trends
» 4 - 20 mA analog or Modbus® digital outputs

LPT Low Power Transmitter

» 2-wire loop, 3-wire VDC or 4-wire VAC power
» 4 - 20 mA linear output signal
» Single sensor: Carbon Monoxide (CO) or Nitrogen Dioxide (NO2)

LPT-A Analog Transmitter

» Full featured, standalone transmitter
» 3-wire VDC or 4-wire VAC power
» 4 - 20 mA or 0 - 10 VDC linear output signal
» Standard LCD display, dry contact relay & audible alarm

LPT-A-VLT Ammonia Vent Line Transmitter

» LCD display (with user selectable function)
» 1 dry contact relay, 30 volt 2 amp maximum
» Internal audible alarm
» Linear 4 - 20 mA or 0 - 10 volt output signal
» 3-wire VDC or 4-wire VAC power

LPT-B BACnet® Transmitter

» 1, 2 or 3 channel operation
» BACnet® MS-TP digital output signal
» One 2A SPDT dry contact relay
» LCD display
» Internal audible alarm

LPT-M Modbus® Transmitter

» 1, 2 or 3 channel operation
» Modbus® RS-485 RTU digital output signal
» One 2A SPDT dry contact relay
» LCD display
» Internal audible alarm

LPT-P Digital Car Park Transmitter

» Full featured, standalone transmitter
» 4-wire 24 VDC power
» Modbus® RS-485 RTU digital output signal
» Standard LCD display, dry contact relay & audible alarm

Remote & Peripheral Devices

ESH-A Remote Sensor

» Allows remote location monitoring of combustible (catalytic), refrigerant or TVOC gases
» 12 - 24 VDC power (nominal)
» Current or voltage output signal
» Easy to install and maintain

FCS-RDM Remote Display

» Provides convenient viewing of gas readings and system statuses in an alternate location
» Full colour LCD touch screen display and LED indicators
» Internal audible alarm

QCC-RDM Remote Display

» Provides convenient viewing of gas readings and system statuses in an alternate location
» 4-line, 20 character LCD display and LED indicators
» Internal audible alarm

LNK-AI Analog Input Peripheral Device

» Four 4-20 mA input channels
» One 2A SPDT dry contact relay
» Scaling and zoning capabilities supported by the controller

LNK-AO Analog Output Peripheral Device

» Four 4-20 mA output channels
» One 2A SPDT dry contact relay
» Scaling and zoning capabilities supported by the controller

LNK-XT Network Extender Peripheral Device

» Extends transmission range of the Modbus® network
» Boosts communication signal strength

Remote Relays for QCC & FCS (RLY-4 / RLY-8)

» Increases the number of available relays
» Rated 5 amps @ 240 VAC each

RPS-24VDC Remote Power Supply (for QCC / FCS)

» Supplies power to a large gas detection system
» Boosts power on long wire runs that present a voltage loss condition

Sample Draw Pump Unit

» Compatible with many types of gas detectors
» Draw samples of air from hard to access areas
» Small, compact device
» 24 VDC or VAC powered
» Standard water / dust tight enclosure

Options (Factory Installed)

Manual Shutoff Switch (Option -SW)

» Safety lock mechanism prevents operating errors
» Finger protection mechanism 
» Push-lock, turn-reset feature
 

Top Mounted Strobe (Option -L)

» Lightweight, durable
» Weather and corrosion resistant
» 100,000 hour LED

Splash Guard

» Protects sensor and interior of enclosure from water and dust
» When installed, enclosure is IP54 rated
» Factory installed

Accessories

Calibration Kit

» Commonly used tools required for calibration in one convenient toolbox
 

Bump Test Systems

» Hand held, easy to use
» Disposable gas generating cells do not expire
» Non-hazardous shipping (not a dangerous good)

GENie Calibration Systems

» Hand held, rugged design
» User adjustable gas concentration outputs
» Disposable gas vials do not expire and are non-hazardous for transport
» Traceable to NIST standards
 

CAL 2000 LT Calibration System

» Hand held, easy to use
» Up to 10 hours of gas source use
» User defined gas concentration and flow rate outputs
» Traceable to NIST standards and rated for use in hazardous areas

Magnetic Wand

» Used for non-intrusive calibration of the LPT-A and SCC
» Use to access menu options and initiate non-intrusive calibration for the LPT-M, LPT-P, LPT-B, DCC and CXT
 

Metal Protective Guard

» 16 gauge, clear anodized metal protective guard
» Larger size for controllers & self-contained systems
» Smaller size for analog & digital transmitters

Remote Audible Alarm

» Loud remote audible alarm
» Easy installation
» 2-wire VDC
» Standard corrosion resistant enclosure
» Water tight option available for wet or wash down environments

RSH-24VDC Remote Strobe & Horn Combo (with Enclosure)

» Two alarm features combined into one device
» Light weight, weather and corrosion resistant
» Independent settings for horn, strobe or horn and strobe together
» Surface mount and 1/2” NPT conduit mount
» ABS / Polycarbonate water / dust tight enclosure

RSH-24V Remote Strobe / Horn (no enclosure)

» Multi alarm features combined into one device 
» Independent settings for horn, strobe or horn and strobe together
» Light weight, weather and corrosion resistant

Remote Strobe Light

» Low profile, lightweight
» Weather and corrosion resistant
» Surface mount and 1/2” NPT conduit mount

RSH-TMR Remote Strobe / Horn with Timer

» Multi alarm features combined into one device 
» Independent settings for horn, strobe or horn and strobe together
» Seven timer setting ranges
» Silence shut off switch

Remote Industrial Horn

» Corrosion resistant finish
» Volume adjustable
» Low current, high decibel




Bookmark and Share

Contact Us

General Inquiry
Application Support
Quote Request
Maintenance Support
Technical Support
RMA Request
  Warranty
Distribution Opportunity