Archive | Controllers

CETCI Launches the FCS Flexible Control System, a High Performance Gas Detection Controller with Logic Control

CETCI Launches the FCS Flexible Control System, a High Performance Gas Detection Controller with Logic Control

Delta, British Columbia, Canada – Critical Environment Technologies Canada Inc. (CETCI) is pleased to announce the release of our FCS Flexible Control System. The FCS replaces the PDC, offering dramatic technological and functional improvements over its predecessor.

The FCS Flexible Control System is a sophisticated, high performance Controller that offers up to 128 gas channel configurations for monitoring toxic, combustible and refrigerant gases with versatile control functionality for non-hazardous, non-explosion rated, commercial and light industrial applications. The FCS is designed to accept inputs from digital and analog transmitters and/or Peripheral Devices (in various combinations), using Modbus® RS-485 or 4-20 mA analog input. In addition, the FCS is available with Modbus® RS-485 output or BACnet® MS/TP output for communicating with a Building Automation System (BAS).

FCS

Standard features include, a full colour, LCD touch screen with LED indicators for Power, Status and Fault, a door mounted audible alarm, an extensive menu structure with password protection, a USB port for firmware upgrades and data downloads, four internal 5-amp, dry contact relays, two configurable switch inputs and two strobe/horn output drives. The built-in data logging capabilities have a large capacity memory for saving all channel readings, configuration changes and transition data. The FCS has a maximum of 32 priorities which can be configured to define the relationships between the channels and the relays, allowing up to. Up to three conditions can be assigned to each relay. Channels can be assigned to report their Low, Medium, High and/or Fault statuses which in turn can be configured to trigger one re more relays to act on one or more of those statuses and channels. The logic control and flexibility of the priority levels is immense, allowing numerous monitoring and alarming configurations.

Optional, value added features include, internal analog inputs (AI) and/or analog outputs (AO), a top mounted strobe and a locking door. The FCS, like our new suite of products, uses our signature black enclosure that is IP54 rated when the optional water tight buzzer is installed at time of order.

Depending on the type and size of the application, the FCS may require additional devices to create the complete system. For networks that extend over a large area there is the potential for data noise and a reduction in the signal. The LNK-XT Network Extender is a signal booster that extends the range of the Modbus communications. An LNK-XT is recommended every 610m (2000ft) and up to 6 of these devices can be used on one FCS network. For very large system application and/or very long wire runs, the Remote Power Supply is available to boost the voltage and provide a renewed amount of power to compensate for voltage drops. The RPS-24VDC converts 90-240 VAC power to 24 VDC power. If more than the four internal relays are needed, two remote devices are available – the RLY-4 which offers four contacts and the RLY-8 that offers eight. All relays are rated at 5 amps. A maximum of 56 relays can be accommodated by the FCS. In the event that the optional internal analog inputs and/or analog outputs are insufficient, there two peripheral devices, the LNK-AI and the LNK-AO available. The LNK-AI offers 4 analog inputs and the LNK-AO offers 4 analog outputs. Depending on the internal AI and AO configurations, up to a maximum of 14 LNK-AO and 14 LNK-AI devices can be connected to the FCS.

The FCS is ideal for use in large, enclosed parking facilities, indoor recreation facilities, food processing plants, refrigeration plants, chemical storage rooms, manufacturing plants and many more.

Posted in Controllers, News, ProductsComments Off on CETCI Launches the FCS Flexible Control System, a High Performance Gas Detection Controller with Logic Control

A Dual Channel Gas Detector for Monitoring Hazardous Gases in the Workplace

A Dual Channel Gas Detector for Monitoring Hazardous Gases in the Workplace

Critical Environment Technologies Canada Inc, (CETCI) offers strategic and reliable gas detection solutions for many applications. Our DCC Dual Channel Controller is an ideal fixed gas detection system for monitoring indoor air to protect workers from exposure to unhealthy levels of combustible, toxic and refrigerant gases, oxygen deficiency, and volatile organic compounds in the workplace.

The potential for exposure to hazardous gases is a concern in many workplace environments. In fact, every workplace must meet local (provincial/state, COOHS/OSHA, etc.) health and safety standards for hazardous gas exposure during working hours. To ensure the safety of the workers, equipment, and the facility, areas presenting a gas hazard should be monitored by gas detectors. In the larger, open areas, a fixed gas detection system is suitable; in confined spaces that workers enter and where gas may be present, portable gas detectors are more appropriate.

Commercial buildings that share a warehouse with manufacturing and/or service work in the back and offices in the front are a prime place for harmful gases and vapours to be present in the entire workplace area.  Airports, hotels, restaurants, supermarkets, shopping malls, manufacturing plants, food processing plants, vehicle repair shops, wineries, breweries and many more are all examples of workplaces where hazardous gases are used or produced onsite.

CETCI’s DCC Dual Channel Controller offers a fixed, continuous hazardous gas monitoring solution with two gas channels, two programmable relays, two 4-20 mA outputs and one configurable 4-20 mA input, an internal audible alarm, an LCD display with LED indicators and a password protected menu system. The two gas channels can be configured with one or two internal gas sensors, one internal and one remote gas sensor or one remote gas sensor, depending on the application requirements. The internal gas sensor options include toxic gases such as carbon monoxide, nitric oxide, nitrogen dioxide, oxygen, etc. The remote sensor options include refrigerants, TVOCs and combustible gases such as hydrogen, methane and propane. The DCC can also be connected to a remote 4-20 mA transmitter/gas detector such as our AST-IS (CO2), ART (IR refrigerants), LPT (CO or NO2) or LPT-A (various gases). All of our gas detectors come standard in a water/dust tight enclosure with a copper coated interior to reduce RF interference.

Optional, value added features for the DCC include an extra loud door mounted buzzer for noisy environments, a top mounted strobe, an internal heater for cold environment applications, and a door mounted water tight buzzer and splash guard for wet or spray down environments.

The DCC Dual Channel Controller conforms to CSA, UL, CE, FCC and IP54 standards.

 

About Critical Environment Technologies Canada Inc.

Critical Environment Technologies designs and manufacturers indoor air quality and fixed gas detection systems including self-contained systems, controllers and transmitters (analog, digital and wireless). Applications include commercial HVAC, institutional, municipal and light industrial markets worldwide. Many of these applications are for vehicle exhaust, but areas of specialization include refrigeration applications, food processing plants, manufacturing plants, wastewater treatment plants, fisheries, wineries/breweries, pulp and paper mills, recreational facilities, bakeries, greenhouses, and many more.

For more information about our products, check out our website at www.critical-environment.com or to discuss a tailored gas detection solution for your application, contact us at 1-877-940-8741.

 

Posted in Controllers, Products, Self ContainedComments Off on A Dual Channel Gas Detector for Monitoring Hazardous Gases in the Workplace

Four Channel Gas Detector for Wastewater Treatment Plants

Four Channel Gas Detector for Wastewater Treatment Plants

Critical Environment Technologies Canada Inc, (CETCI) offers strategic and reliable gas detection solutions for many applications, including wastewater treatment plants. Our QCC Quad Channel Controller, is an ideal fixed gas detection system for this type of application.

A wastewater treatment facility is a wet maze of rooms, pipes, pumps, wells, chambers, concrete tanks and settling basins. Each treatment stage the wastewater goes through involves hazardous gases that may be already present, are produced or are added to complete the process. To ensure the safety of the workers, equipment and the facility, every area presenting a gas hazard should be monitored, including the gas storage rooms, ozone generator room and any room that gas passes through. In the larger, open areas, a fixed gas detection system is suitable; in confined spaces that operators enter and where gas may be present, portable gas detectors are more appropriate.

The most common hazardous gases found in this type of facility are hydrogen sulphide, methane, ammonia, carbon monoxide, chlorine and oxygen deficiency. Some facilities may also use ozone, chlorine dioxide or sodium hypochlorite with the chlorine during the sanitization treatment process. Furthermore, sulphur dioxide is often used to de-chlorinate the water once the treatment process is complete.

CETCI’s QCC Quad Channel Controller offers a fixed, continuous gas monitoring solution with four gas channels, three programmable relays, a door mounted audible alarm and an optional BACnet RS-485 output signal for communicating with a building automation system. The four gas channels can be configured with any combination of analog or digital transmitters with the same or different types of gas sensors. For large applications, multiple QCC controllers can be networked together, each providing another four available gas channels and 3 relays. Other value added, optional features include 2 analog outputs with a data logger, manual equipment ON/OFF switch, top mounted strobe, remote strobe and horn combo and a remote display module that offers the ability to view the gas level readings in a separate location from the controller and transmitters.

The potential for physical damage to the gas detection equipment is high in this type of harsh, wet environment. CETCI’s equipment is constructed to withstand the unpredictable water levels and acidic or caustic conditions from gases like hydrogen sulphide and chlorine when it mixes with water.

 

About Critical Environment Technologies Canada Inc.

Critical Environment Technologies designs and manufacturers indoor air quality and fixed gas detection systems including self-contained systems, controllers and transmitters (analog, digital and wireless). Applications include commercial HVAC, institutional, municipal and light industrial markets worldwide. Many of these applications are for vehicle exhaust, but areas of specialization include refrigeration, food processing plants, manufacturing plants, wastewater treatment plants, commercial swimming pools and many more.

For more information about our products, check out our website at www.critical-environment.com or to discuss a tailored gas detection solution for your application, contact us at 1-877-940-8741.

Posted in Applications, Controllers, News, ProductsComments Off on Four Channel Gas Detector for Wastewater Treatment Plants

CETCI Coats All Non-Metallic Enclosures to Eliminate EMI & RFI

CETCI Coats All Non-Metallic Enclosures to Eliminate EMI & RFI

Critical Environment Technologies Canada Inc. (CETCI) professionally coats the interior of all non-metallic system enclosures with a protective electromagnetic interference (EMI) coating for all their gas detection monitors and selective YES branded air quality instruments. This coating is designed to reduce or eliminate potential EMI and radio frequency interference (RFI).

For more than five years, CETCI has tested the EMI coating on the YESAIR. With good results, CETCI has decided to coat all their non-metallic enclosure products with the EMI coating. EMI / RFI shielding provides a high-level of protection without affecting the appearance or operation of the enclosure.

With the amount of electronic equipment being used nowadays, millions of waves and signals float through the air. Therefore, it’s important to protect the product from incorrect frequencies from interfering with the device. Applications, such as ambulance stations, may benefit the most from this as they have large transceivers and compressor / refrigeration rooms that use high voltage equipment.

Benefits to having a non-metallic enclosures includes reduced shipping cost due to the lighter weight of the product, easier installation due to being able to take apart the cover and base, reduced cost to produce a product resulting in savings passed onto the customers, and easier handling due to size and weight. With the many benefits of using non-metallic enclosures, CETCI feels that they are providing more value and a better product to their end users.

For more information on the entire range of gas detection systems and IAQ instruments, please visit www.critical-environment.com.

 

Want to be the first to be notified on updates?
Simply visit www.critical-environment.com, subscribe to CETCI Magazine Blog, find us on Facebook, follow us on Twitter: @cetci, connect with us on LinkedIn, or subscribe to our RSS feed.

Posted in Controllers, Enclosures, Indoor Air Quality, Products, Self Contained, TransmittersComments Off on CETCI Coats All Non-Metallic Enclosures to Eliminate EMI & RFI

Gas Detection Controllers

Gas Detection Controllers

CETCI’s family of gas detection controllers are designed to accept inputs from a number of remote transmitters (analog and/or digital) and perform control functions such as automatically activating exhaust fans, make-up air fans, alarm devices, etc. PAC and PDC controllers utilize microprocessor circuits allowing these controllers to be completely field configurable by the end user. A 2-line, backlit LCD provides the user with scrolling information about the connected transmitters and the built-in audible / visual alarms provide alarm notification to the user. The PAC accommodates 4 analog inputs and provides 4 analog outputs (4-20 mA). The PDC accommodates 8 analog inputs and 120 digital transmitters or 128 digital transmitters on a communication network. Both controllers provide a wide range of functionality.

pdc

Posted in Controllers, Products3 Comments


Archives

  • I posted a new photo to Facebook ,
  • CETCI Launches the FCS Flexible Control System, a High Performance Gas Detection Controller with Logic Control... ,
  • We are going to the AHR Expo in Vegas. Are you? If so, drop by our booth to say Hi! Check us out on Map Your Show... ,
  • I posted a new photo to Facebook ,
  • Tutorial – How to Calibrate the DST-ECO: via @YouTube,
  • Last day of the AHR Expo in Mexico. Word is, it's been a great show!,
  • We make gas detectors for monitoring toxic, combustible and refrigerant gases for a wide range of applications.... ,
  • BTL Listing granted for CETCI BACnet® Module... ,

Gas Detectors

CETCI gas detectors are used to detect many different gases. Some of the most common are Carbon Monoxide, Carbon Dioxide, Nitrogen Dioxide, Nitric Oxide, Ammonia, Chlorine, Ozone, Combustible Gases like Methane and Propane, Oxygen, Refrigerants and more.

IAQ Monitors

The YES Series of IAQ Monitors are essential for those responsible for conducting Indoor Air Quality (IAQ) Investigations. These instruments are specifically designed to measure and record the quality of indoor air in offices, buildings, homes, schools, parking garages, ice rinks, etc.